Amana brand PTACs have an EER of up to 12.8 (on heat pumps, a COP of up to 3.6) to keep energy consumption to a minimum.
On-board Energy Management System
Amana brand units are equipped with EMS technology to better control room temperature and save energy dollars.
DigiSmart Control Board
Ready for wireless or wired operation
Programmable Set-back Program
Owner-controlled settings allows automatic temperature setback when unit is idle.
Network Ready
Amana brand DigiSmart units connected to a Tridium JACE controller automatically build their own wireless network.
DigiSmart Suite of Peripherals
Remote occupancy sensor, remote thermostat, RF antennas, and RF platform controller provide everything you need to reduce energy costs by 35%.
DigiSmart In-Room Products
PTAC - Contains all the processing power and software to manage energy consumption, unit status and comfort performance.
Occupancy Control - The remote sensor above the door determines if the room is occupied or not. If occupied, normal routines run, but if unoccupied the PTAC can change temperature settings based upon owner settings.
Remote Thermostat - The DigiSmart remote thermostat works just like the one at home but unlike other PTACs does not disable the unit controls. Remote and PTAC control panels work at the same time and show the same information.
Set-up - Best of all, no wiring. All of the peripheral devices can be installed by your handy man without calling an expensive electrician. A touch of a button connects the peripherals to the air conditioner in that room.
DigiSmart Property-Wide Network
The Tridium Jace controller connects all Amana DigiSmart PTACs in a property automatically through a self-detection routine.
Once connected to your PC, the status and operating condition of each unit can be viewed remotely and settings changed centrally.
The Tridium Jace controller through its NiagaraAX protocol has already built connections to more than 100 commercially available building management systems.
So once the network is up and running, Amana PTACs can be integrated with your existing building management system or if desired, controlled remotely through the Internet.
On-Board Energy Management System (EMS)
Set-Back Mode - the owner can determine amount of time unit left 'untouched' (buttons not pushed) before the PTAC begins a set-back routine and new thermostat temperature takes effect, also selected by owner.
Maintenance Status - Separate green LED indicator light to show if unit requires maintenance.
Electronic Temperature Limits - owner can set separate cooling and heating temperature ranges and limit operation to one-degree increments, saving energy by preventing guests from over-cooling or over-heating.
Enhanced Dehumidification Cooling Mode - the unit can be set to lengthen cooling cycles while the room is occupied or unoccupied. This passes more air through the unit while the coil is below the dew point, increasing the amount of moisture removed.
Unit Diagnostics - when switched to diagnostics mode, the unit shows ten different self-diagnosis codes to help keep the unit running most efficiently.
Freeze Protection - when the unit senses temperature of 40° or below, the unit automatically activates the fan motor and the electric or hydronic heat to help prevent burst water pipes or broken fixtures caused by freezing temperatures.
Extended Heating with the Heat Pump - heat pump models will operate in heat-pump mode with external temperatures as low as 24° to provide additional energy savings.
30 Second Fan-Only Delay - the fan continues to run for 30 seconds after the compressor has stopped or after electric heat has been turned off. This improves efficiency by dispersing the cooled or heated air still on the coil into the room.
Indoor comfort all year - PTACs can rapidly remove heat and moisture from indoor air. You simply set the units thermostat to the temperature that you desire and the unit automatically cools to that level. You can manually select fan speed or use the automatic fan speed setting. When you need the room to be heated you use the same basic settings. Just set the thermostat to the temperature you want and select the heating function.
Simple Installation - PTACs are easy to install because they come in standard sizes and shapes. Regardless of the heating and cooling load requirements, the unit is the same size. Since both the heating and cooling systems exist inside a single unit, installation is easier than the installation of a split system.
Independent Operation - Unlike split-system heating and cooling systems which condition whole buildings through the use of ductwork, PTACs cool and heat only the rooms or spaces where they are installed. This means you cool or heat only what you want with individual temperature control. With multiple PTACs installed, you can easily control indoor temperature on a room to room basis.
On-Board Energy Management System (EMS)
Set-Back Mode
The owner can determine amount of time unit is left 'untouched' (buttons not pushed) before the PTAC begins a set-back routine and new thermostat temperature takes effect.
All set-back routines can be changed by owner.
Maintenance Status
Separate green LED indicator light to show if unit requires maintenance.
Electronic Temperature Limits
Owner can set separate cooling and heating temperature ranges and limit operation to one-degree increments, saving energy by preventing guests from over-cooling or over-heating.
Enhanced Dehumidification Cooling Mode
The unit can be set to lengthen cooling cycles while the room is occupied or unoccupied.
This passes more air through the unit while the coil is below the dew point, increasing the amount of moisture removed.
Unit Diagnostics
When switched to diagnostics mode, the unit shows ten different self-diagnosis codes to help keep the unit running most efficiently.
Freeze Protection
when sensors show an outdoor temperature of 40°F or below, the unit automatically activates the fan motor and the electric or hydronic heat to help prevent burst water pipes or broken fixtures caused by freezing temperatures.
Extended Heating with the Heat-Pump
Heat pump models will operate in heat-pump mode with external temperatures as low 24°F to provide additional energy savings.
30-Second Fan-Off Delay
The fan continues to run for 30 seconds after the compressor has stopped or after electric heat has been turned off.
This improves efficiency by dispersing the cooled or heated air still on the coil into the room.
Amana Brand PTACS are:
Energy Efficient:
Amana brand PTACs offer EER up to 12.8 and on heat pumps COP as high as 3.6
Easy to Clean:
Inside the room, the removable pullout polymer filter is easy to clean and is ready for an optional activated charcoal filter to remove odors
Outside, the removable condenser shroud means east access for coil cleaning, helping to maintain unit performance
Easy to Use:
One touch digital controls are simple and easy to use
Maximize Room Space:
Slim 7 3/8" in-room depth and ability to install with zero floor
Low Temperature Operation:
Heat pump operates as low as 24° and units come with "Freeze Protection" standard, running fan and heat when temperature dips below 40°
Automatic Energy Heat:
No more "No Heat" complaints in the middle of the night as heat pumps switch on electric heater if heating load greater than unit capacity.
Full line of accessories including:
DigiSmart suite of Peripherals - Wireless Thermostat; Wireless Occupancy Sensor; Network Controller
Wall Sleeves in Stonewood (standard) or custom colors by order
Grilles in aluminum (stamped and extruded) or plastic in Stonewood (standard) or custom colors by order
Wired Thermostats
DigiSmart Suite of products
Automatic Network Setup
The DigiSmart RF network automatically configures and heals itself.
No need to log unit on or off the network.
High-Capacity Network
DigiSmart runs independently on each PTAC or up to 170 units in a single network installation
Set-Back Mode
The owner can determine amount of time unit is left 'untouched' (buttons not pushed) before the PTAC begins a set-back routine and new thermostat temperature takes effect.
All set-back routines can be changed by owner.
Electronic Temperature Limits
Owner can set separate cooling and heating temperature ranges and limit operation to one degree increments, saving energy by preventing guests from over-cooling or over-heating.
Enhanced Dehumidification Cooling Mode
The unit can be set to lengthen cooling cycles while the room is occupied or unoccupied.
This passes more air through the unit while the coil is below the dew point, increasing the amount of moisture removed.
Maintenance Status
Separate green LED indicator light to show if unit requires Maintenance at the unit level.
Network interface shows status of each PTAC and peripheral (thermostat or sensor)
Unit Diagnostics
When switched to diagnostics mode, the unit shows ten different self-diagnosis codes to help keep the unit running most efficiently.
Email Notification
Once linked to a PC, the DigiSmart network can automatically send an e-mail to notify a property of maintenance issues.
Energy Management System (EMS) software
Is written in 'flash' memory in the control board and not 'hard coded'.
That means EMS software can be updated at the PTAC or through the DigiSmart network without needed to visit each unit.
PTAC Warranty:
We are pleased to offer the following warranty on all Amana® PTACs:
Full One Year Warranty
Full Second Through Fifth Year Warranty on Sealed System Components
Limited Second Through Fifth Year Warranty on Functional Parts
Warranty provides for:
Full First Year Warranty: We will repair or replace, free of charge, f.o.b. Fayetteville, Tennessee, any part of the unit or Amana®-brand accessory, which proves to be defective due to workmanship or materials.
Full Second Through Fifth Year Sealed System Warranty: During the 2nd through 5th years, we will repair or replace, free of charge, f.o.b. Fayetteville, Tennessee, the evaporator coil, condenser coil, compressor or connecting tubing, which proves to be defective due to workmanship or materials or non-repairable refrigerant leaks(s).
Limited Second Through Fifth Year Functional Parts Warranty: During the 2nd though 5th year, we will provide, free of charge, f.o.b. Fayetteville, Tennessee, functional parts on the PTC or PTH unit, which prove to be defective due to workmanship or materials.Components covered include: unit fan motor, unit mounted thermostats and thermistors, circuit boards, factory-installed hydronic transformer and relay, factory-installed heaters and relays, unit blower wheel and fan propeller, reversing valve solenoid and capacitor.The limited warranty does not include diagnostic time, labor, or any transportation and reinstallation charges that may be required.